Skip to main content

Table 3 Procedure characteristics

From: Viabahn stent graft for arterial injury management: safety, technical success, and long-term outcome

Parameter

Total no. of patients n = 40

 

Total no. of deployed devices n = 43

Approach site

 

 Femoral

39/40 (97.5)

 Brachial

1/40 (2.5)

No. of devices implanted

 

 1

38/40 (95.0)

 2

1/40 (2.5)

 3

1/40 (2.5)

Device diameter (n, % of 43 deployed)

 5 mm

7/43 (16.3)

 6 mm

15/43 (34.9)

 7 mm

8/43 (18.6)

 8 mm

9/43 (20.9)

 > 8 mm

4/43 (9.3)

Device length (n, % of 43 deployed)

 2.5 cm

8/43 (18.6)

 5.0 cm

17/43 (39.5)

 7.5 cm

0/43 (0.0)

 10.0 cm

14/43 (32.6)

 15.0 cm

3/43 (7.0)

 25.0 cm

1/43 (2.3)

Neck length (mm)

20 [12–30]

Intraoperative adverse events

0/40 (0.0)

Technical successa

40/40 (100)

  1. Values are given as frequency n (%) or median [IQR]
  2. aTechnical success was defined as the completed placement of the Viabahn stent graft with full bridging of the vessel injury, as determined by final target site angiography