Table 4 Independent predictors of restenosis after repeat and de novo DCB angioplasty

From: Repeat drug-coated balloon angioplasty for femoropopliteal lesions: 12-month results from a retrospective observational study

 

Univariable analysis

Multivariable analysis

Hazard ratio (95% CI)

p-value

Hazard ratio (95% CI)

p-value

Chronic total occlusion

1.09 (0.47–2.56)

0.836

1.52 (0.39–5.89)

0.550

Chronic limb threatening ischemia

3.14 (1.28–7.71)

0.012

2.92 (0.91–9.31)

0.071

Hemodialysis

2.52 (1.01–6.24)

0.046

2.03 (0.54–7.67)

0.295

High-dose DCB

0.77 (0.26–2.29)

0.635

1.27 (0.35–4.64)

0.722

IVUS use

0.46 (0.15–1.36)

0.162

0.22 (0.04–1.12)

0.069

PACSS grade 4

1.51 (0.61–3.72)

0.369

1.31 (0.46–3.78)

0.612

Repeat DCB angioplasty

2.63 (1.07–6.51)

0.036

5.13 (1.43–18.4)

0.012

Small vessel size < 4.5 mm

3.24 (0.76–13.8)

0.113

6.25 (1.17–33.4)

0.032