Digital subtraction angiography of the superior mesenteric artery (SMA). a Superior mesenteric arteriography demonstrated a dissection originating in the SMA and involving the jejunal arteries. b The re-entry through the true lumen was occluded with the micro-balloon to prevent coil migration. Using a 2-marker catheter through the false lumen, eight detachable coils were placed in the false lumen. c The micro-balloon was slowly pulled to the point of entry and re-expanded, and three detachable coils were placed in the false lumen. *: false lumen; white arrowhead: true lumen; red arrowhead: jejunal artery; white arrow: coils; red arrow: micro-balloon