Skip to main content

Table 1 Eleven patients who underwent coil embolization using the intentional early detachment technique with detachable coils

From: Enhancing precision in vascular embolization: evaluating the effectiveness of the intentional early detachment technique with detachable coils in complex cases

Patient No /Age /Sex

Embolized artery

Etiology

Coil: diameter in mm/

length in cm

No of coils

Microcatheters/

microguidewire

Reasons for intentional early detachment

Technical/Clinical success

Complication

1/52/M

AIPDA

Hemorrhage due to SAM

Avenir PICO: 1/2(× 2)

2

Carnelian MARVEL S 1.3, Swift Ninja/CHIKAI X10

Deployment of coils through a 1.3-Fr catheter

YES/YES

NO

2/69/M

3rd ICA

Preemptive embolization to prevent T2EL

Target XL: 5/10(× 2), 4/15(× 5)

Azur soft3D: 4/10

8

Carnelian MARVEL S,

Swift Ninja/Traxcess

Significant tortuosity in vascular anatomy

YES/YES

NO

3/74/M

Cystic artery

Idiopathic gallbladder bleeding

Target nano: 1/2(× 2)

2

Guidepost, DeFrictor Nano, Carnelian MARVEL S/CHIKAI X10

Deployment of coils through a 1.3-Fr catheter

YES/YES

NO

4/75/M

PIPDA

Hemorrhage within a pancreatic tumor

Target XL soft: 6/20

1

Carnelian MARVEL S,

Swift Ninja/CHIKAI V, CHIKAI X10

Significant tortuosity in vascular anatomy

YES/YES

NO

5/75/F

DPA

True aneurysm due to MALS

Target nano: 1/2, 1/3(× 3)

4

Carnelian MARVEL S,

Swift Ninja/CHIKAI V, CHIKAI X10

Inadequate system backup

YES/YES

NO

6/76/M

2nd LA

T2EL

Avenir: 4/20, 3/10, 4/13(× 2), 5/17(× 2)

Target tetra: 3.5/8(× 2)

8

Carnelian MARVEL S 1.3, Masters HF/CHIKAI X10

Deployment of coils through a 1.3-Fr catheter

YES/YES

NO

7/79/F

PIPDA

Post-EST hemorrhage

SMART Coil: 1/2

1

Carnelian MARVEL S 1.3, Masters HF/CHIKAI X10

Deployment of coils through a 1.3-Fr catheter

YES/YES

NO

8/83/M

Iliolumbar artery

Lt-IIAA

Embolization to prevent T2EL

Avenir: 3/10, 2/8, 2/6

3

Carnelian MARVEL S,

Swift Ninja/CHIKAI V, CHIKAI X10

Inadequate system backup

YES/YES

NO

9/86/M

VR

Diverticular hemorrhage

Avenir: 1.5/3(× 2),2/4, 2/3(× 2)

iED coil: 1/3

6

Carnelian MARVEL S,

Masters HF/CHIKAI V, CHIKAI X10

Inadequate system backup

YES/YES

NO

10/86/M

4th LA

T2EL

Avenir: 4/20

1

Carnelian MARVEL S,

Swift Ninja/CHIKAI X10

Significant tortuosity in vascular anatomy

YES/YES

NO

11/87/M

4th LA

T2EL

AZUR soft3D: 3/8

Avenir: 4/20

2

Carnelian MARVEL S,

Swift Ninja/CHIKAI X10

Significant tortuosity in vascular anatomy

YES/YES

NO

  1. Target XL soft/Nano/Tetra (Stryker, Fremont, CA, USA), SMART COIL (Penumbra, Alameda, CA, USA), AVENIR/AVENIR PICO (Wallaby Medical, Shanghai, China), AZUR soft 3D (Terumo, Tokyo, Japan), iED coil (KANEKA Medix, Osaka, Japan)
  2. Carnelian MARVEL S/S 1.3 (Tokai Medical Products, Aichi, Japan), Swift NINJA (SB KAWASUMI, Tokyo, Japan), Masters HF (Asahi Intecc, Aichi, Japan), DeFrictor Nano (Medico's Hirata, Osaka, Japan), Guidepost (Tokai Medical Products), CHIKAI V/X10 (Asahi Intecc, Aichi, Japan), Traxcess (Terumo, Tokyo, Japan)
  3. AIPDA anterior inferior pancreaticoduodenal artery, PIPDA posterior inferior pancreaticoduodenal artery, DPA dorsal pancreatic artery, LA lumbar artery, MALS median arcuate ligament syndrome, EST endoscopic sphincterotomy, ICA intercostal artery, IIAA internal iliac artery aneurysm, VR vasa recta, T2EL type 2 endoleak, SAM segmental arterial mediolysis